High precision
Voltage and current accuracy ≤ ±0.02 F.S., with 24-bit high-resolution sampling, ensuring test results are accurate and fully traceable.
Fast response
Current response ≤3 ms, switching time ≤5 ms, supports 20 ms high-speed pulse testing, accurately capturing dynamic characteristics.
Intelligent multi-range adaptation
One equipment can adapt to multiple types of test tasks, covering the needs of refined small current and large current rate testing.
Fully modular architecture
Single-channel independent control, fast fault isolation, high maintenance efficiency, and no impact on overall equipment operation.
Flexible scaling
The equipment supports parallel expansion and multi-unit cascading, compatible with all form factors: cylindrical, pouch, and prismatic cells.
Multi-device collaborative testing
Can be connected to environmental chambers, water chillers, and impedance modules to simultaneously collect multi-dimensional data of temperature and pressure.
TECHNICAL PARAMETERS
| Model | 6V-60A-64CH | 6V-150A-32CH | 6V-300A-24CH | 6V-600A-16CH | |
| Input Voltage | AC 380V±10% | ||||
| Input Frequency | 50Hz / 60Hz | ||||
| Data Recording Time | 10ms | ||||
| Voltage | Voltage Range | Charge 0V~6V Discharge 1V~6V | |||
| Voltage Accuracy | Standard: ±0.05%F.S. PRO: ±0.03%F.S Rx : ±0.01%F.S | ||||
| Current | Current | ±30mA~±60A | ±75mA~±150A | ±150mA~±300A | ±300mA~±600A |
| Current Accuracy | Standard: ±0.05%F.S. PRO : ±0.03%F.S Rx : ±0.01%F.S | ||||
| Current Response Time (10%~90% F.S., Battery Load) | Standard:≤5ms PRO : ≤3.ms Rx : ≤1ms | ||||
| Current Switching Time (-90%~+90% F.S., Battery Load) | Standard: ≤10ms PRO : ≤5ms Rx : ≤2ms | ||||
| Single-Channel Power | 360W | 900W | 1800W | 3600W | |
| Power Accuracy | ±0.05 %F.S. 25℃±10 ℃ | ||||
For more specifications, pls freely contact us.